English

English

Get a Quote
Products

Hot Products

Company News

What Causes Ball Valve Failure? 5 Common Issues and How to Prevent Them
What Causes Ball Valve Failure? 5 Common Issues and How to Prevent Them
2025-04-11

Ball valves are widely used industrial flow control components, commonly found in applications such as water treatment, oil and gas, chemical processing, HVAC systems, and the food and pharmaceutical industries. Thanks to their compact structure, quick shut-off capability, and excellent sealing performance, ball valves play a critical role in various fluid systems. However, even the most reliable ball valve can encounter failures after prolonged operation. When a ball valve fails, it can compromise the stability of the entire system and, in severe cases, lead to media leakage or even safety incidents. Therefore, understanding the root causes of ball valve failure and implementing effective preventive measures is essential for engineers and maintenance personnel.   1. Seal Failure Cause: Seal failure in ball valves is often caused by seat wear, debris accumulation, or aging of sealing materials. This issue is especially common in high-temperature, high-pressure, or corrosive media environments. Prevention Tips: To extend the service life of the seal, choose ball valves with PTFE or metal seats that are compatible with the process media. Regularly clean the seat area and establish a replacement schedule based on the operating conditions.   2. Corrosion or Scratches on the Ball Surface Cause: When a ball valve is used with media containing acids, alkalis, high salt content, or abrasive particles, improper material selection can lead to corrosion, pitting, or surface scratches. These issues reduce sealing performance and affect smooth operation. Prevention Tips: Select stainless steel ball valves (such as 304 or 316 grades) or special alloy ball valves based on the specific media characteristics. Additionally, install a strainer or filter to minimize solid particle intrusion and protect the valve internals.   3. Stem Breakage or Seizure Cause: The valve stem, which transmits torque to the ball, may experience metal fatigue and fracture under frequent operation or excessive torque. Seizure can also occur due to bearing wear or lack of lubrication. In some low-quality ball valves, insufficient structural design margin further increases the risk of stem failure. Prevention Tips: Use ball valves with blow-out proof stem designs to enhance operational safety. Ensure that operating torque stays within the valve’s rated limits, and apply lubricant regularly to reduce friction and wear, extending service life.   4. Improper Installation or Operation Cause: Human errors such as incorrect installation direction, loose flange connections, or frequent forceful operation are major contributors to early ball valve failure. In the case of electric or pneumatic ball valves, signal control errors can also lead to misoperation or valve jamming. Prevention Tips: Always follow the manufacturer’s installation guidelines, ensure proper alignment and secure flange connections. Install limit switches and torque protection devices to safeguard...

Can Wafer Check Valves Be Installed Vertically? Installation Best Practices and Considerations
Can Wafer Check Valves Be Installed Vertically? Installation Best Practices and Considerations
2025-03-28

In industrial pipeline systems, the wafer check valve plays a key role in preventing backflow and is widely used in various fluid control systems. It is favored by many engineers and designers for its compact, lightweight, and easy-to-install characteristics. In practical applications, many consider installing the wafer check valve vertically to accommodate different pipeline layouts and space requirements. So, can wafer check valves be installed vertically? If so, how can their performance and safety be ensured? This article will explore the feasibility of vertical installation of wafer check valves and share some installation guidelines and precautions.   1. Working Principle and Application Scope of Wafer Check Valves A wafer check valve is an automatically opening and closing valve primarily used to prevent backflow of fluids. The valve disc is pushed open when the fluid flows in the forward direction, and it closes by gravity or spring action when the fluid stops or reverses. Unlike traditional swing check valves, wafer check valves typically feature a more compact design, allowing them to be directly sandwiched between pipeline flanges, saving installation space. In typical pipeline systems, the most common installation method for wafer check valves is horizontal installation, as this configuration is the most stable and convenient for maintenance. However, in certain special installation environments, such as tight spaces or specific operating conditions, vertical installation can also be a viable option.   2. Can Wafer Check Valves Be Installed Vertically? In theory, vertical installation of a wafer check valve is feasible, but several important factors should be considered:   · Gravity Effect on the Valve Disc The design of the wafer check valve relies on the gravity of the valve disc to close the valve. In horizontal installation, the valve disc naturally falls to ensure a proper seal. However, in a vertical installation, the valve disc may not close naturally due to gravity, especially in upward flow situations. Therefore, it is crucial to ensure that the design of the valve disc and the configuration of the spring are suitable for vertical installation, allowing the valve to close effectively without external interference.   · Fluid Flow Direction The direction of fluid flow in a wafer check valve directly impacts its performance. When installed vertically, the flow direction may change, potentially leading to unstable opening or closing of the valve disc. To ensure that the valve disc closes at the right time, it is recommended to check whether the valve has a reliable anti-backflow design, ensuring it can function properly even in vertical installation.   · Installation Space and Maintenance Accessibility Vertical installation of a wafer check valve may require more space, particularly if there is a need to maintain a certain distance from other equipment in the pipeline system to allow ...

What is the Ball Valve Used For?
What is the Ball Valve Used For?
2025-03-06

A ball valve is a widely used flow control valve in industrial pipeline systems. With its simple structure, excellent sealing performance, and easy operation, it plays a crucial role across various industries. 1. Basic Functions Ball valves are rotary-type valves that control fluid flow by rotating a spherical closure element 90 degrees. Their primary functions include: (1) Shut-off and On/Off Control Provides quick opening and closing, making it suitable for pipeline systems requiring frequent operation. (2) Flow Regulation Certain specially designed ball valves allow flow adjustment to accommodate different operating conditions. (3) Bi-directional Sealing Ensures reliable sealing in both flow directions, enhancing pipeline system safety. (4) Emergency Shut-off Some ball valves are equipped with actuators for emergency shut-off, improving overall system safety.   2. Key Features Due to their unique structure and material selection, ball valves offer the following advantages: (1) Excellent Sealing Performance Utilizes soft seals (PTFE, rubber) or metal seals to ensure zero leakage. (2) High Pressure and Temperature Resistance Capable of withstanding high pressures (up to Class 2500) and extreme temperatures (some metal-seated ball valves can operate above 500°C). (3) Easy Operation Available with manual handles, gear operators, electric, or pneumatic actuators to meet various automation requirements. (4) Long Service Life Minimal friction during operation, making it suitable for frequent and long-term use.   3. Typical Applications Due to their versatility, ball valves play a critical role across various industries, including: (1) Oil & Gas Industry Used in transmission pipelines, distribution systems, and storage facilities, ball valves provide reliable control over high-pressure and high-temperature media, ensuring leak prevention and system safety. (2) Chemical & Pharmaceutical Industry Commonly employed for handling corrosive media such as acids, alkalis, and solvents. The use of corrosion-resistant materials (e.g., stainless steel, Hastelloy, PTFE lining) extends service life and enhances reliability. (3) Water Treatment & Environmental Protection In wastewater treatment, seawater desalination, and municipal water supply networks, ball valves regulate and isolate flow, ensuring stable and secure fluid transportation. (4) Power & Energy Sector Ball valves are used for precise control of steam, cooling water, and fuel flow in boiler systems, condensate recovery, and gas transmission, improving energy efficiency and operational safety. (5) Marine & Offshore Engineering Applied in offshore oil platforms and shipboard piping systems, ball valves control seawater, fuel, and ballast water while meeting stringent corrosion resistance requirements in harsh marine environments.

DN200 PN40 Stainless Steel Gate Valve EN1984 HW-OP BB RF OS&Y
加载中...

DN200 PN40 Stainless Steel Gate Valve EN1984 HW-OP BB RF OS&Y

DN200 PN40 gate valve is made according to EN1984 standard. The valve body is made of 1.4571+STL. It has the structural characteristics of bolt cover, elastic gate, rising stem and bracket. Its connection mode is EN1092-1/B. And it has hand wheel operation mode.

  • Payment:

    30% when order confirmed, 70% before shipment
  • Product Origin:

    China
  • Color:

    Customization
  • Shipping Port:

    Shanghai, China
  • Lead Time:

    30~60 days Ex Works after order confirmation
  • Material:

    1.4571+STL
  • Method of Operation:

    HW-OP
Inquiry now
Product Detail

Product Description

Type

Gate Valve

Size

DN200

Pressure

PN40

Connection

EN1092-1/B

Operation

HW-OP

Body Material

1.4571+STL

Design Norm

EN1984

Face to Face Dimensions

Customer Standards

Flange dimension

EN1092-1/B1

Test & Inspection Code

EN12266-1/2

Temperature

-29 ~ 425°C

Applicable Medium

Water, Oil and Gas

Features

1. Low fluid resistance, effortless opening and closing, unrestricted medium flow direction;

2. Simple form, short structural length, good manufacturing process, and wide application range.

Technical Drawing

DN200 PN40 Stainless Steel Gate Valve EN1984 HW-OP BB RF OS&Y

Dimension Checking

DN200 PN40 Stainless Steel Gate Valve EN1984 HW-OP BB RF OS&Y

Pressure Testing

DN200 PN40 Stainless Steel Gate Valve EN1984 HW-OP BB RF OS&Y

Nameplate & Packing

DN200 PN40 Stainless Steel Gate Valve EN1984 HW-OP BB RF OS&Y

Inspection report

DN200 PN40 Stainless Steel Gate Valve EN1984 HW-OP BB RF OS&YDN200 PN40 Stainless Steel Gate Valve EN1984 HW-OP BB RF OS&YDN200 PN40 Stainless Steel Gate Valve EN1984 HW-OP BB RF OS&YDN200 PN40 Stainless Steel Gate Valve EN1984 HW-OP BB RF OS&Y

Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
Stainless Steel Flanged Gate Valve
Stainless Steel Gate Valve DIN 3352 PN16 OS&Y

The stainless steel CF8M gate valve is designed with flange connection and handwheel operation per DIN 3352. The PN16 DN200 full port gate valve has OS&Y structure, resilient wedge and replaceable seat. Design Specifications Design and Manufacture: DIN 3352 End to End Dimension: DIN3202 Flange End: EN1092-1 Test & Inspection: EN12266-1/2 Design Feature -Full Bore Design -Superior flow rates & small friction loss -Low torque value for closing and opening the valve -Flexible wedge for better seating and ease of operation -Smooth finish and superior sealing for seat face -Every valve is manufactured with specific number on body for traceability Quick Detail Type Gate Valve Size DN 200 Pressure PN 16 Construction Bolted Bonnet, Rising Stem, Outside Screw and Yoke Connection Flange Connection Operation Handwheel Body Material Stainless Steel CF8M TrimMaterial Stainless Steel Temperature Range -268℃~+648℃ Medium Water, Oil and Gas Origin China Dervos Packaging Packaging is an important part we could never neglect. Dervos has a packaging process for each order to ensure a safe and clear delivery of the order.

4 150LB Gate Valve API603 Stainless Steel HW-OP OS&Y CF8M
4" 150LB Gate Valve API603 Stainless Steel HW-OP OS&Y CF8M

4" 150LB gate valve is made according to API 603 standard. The valve body is made of ASTM A351 CF8M+STL. It has the structural characteristics of bolt cover, elastic wedge and rising stem. Its test and inspection conform to API 598, and its operation mode is handwheel operation.

DIN DN125 PN16 Stainless Steel Gate Valve HW-OP BB RF
DIN DN125 PN16 Stainless Steel Gate Valve HW-OP BB RF

DN125 PN16 gate valve is made according to DIN 3352 standard. The valve body is made of 1.4408. It has the structural characteristics of bolt cover, rising stem, elastic wedge, with SS316 insulation jacket and structural length of 325mm. Its connection mode is RF EN1092-1 B1. And it has hand wheel operation mode.

2 150LB Stainless Steel Gate Valve RF CF3 API600 Handwheel
2" 150LB Stainless Steel Gate Valve RF CF3 API600 Handwheel

2" 150LB gate valve is made according to API 600 standard. The valve body is made of A351 CF3. It has the structural characteristics of bolt cover, rising stem bracket. Its connection mode is RF. And it has handwheel operation mode.

Ball Valve
16" 900LB Fully Welded Ball Valve BW LF2 Turbine API6D

16" 900LB ball valve is made according to API 6D standard. The valve body is made of A350 LF2. It has the structural characteristics of fully welded, fixed ball and full bore. Its connection mode is BW. And it has turbine operation mode.

Ball Valve
DN25 PN100 Floating Ball Valve A105 Lever EN1092-1 D

DN25 PN100 ball valve is made according to ISO 17292 standard. The valve body is made of ASTM A105. It has the structural characteristics of floating ball, full bore, anti-fire, anti-static, and anti-flying valve stem. Its connection mode is EN1092-1 D. And it has lever operation mode.

Floating Ball Valve
2 inch CL300 2PC Floating Ball Valve Full Bore 1/2" NPT(F) X 2" RF

The 3000LB ball valve, made of F316 or F316L, has an asymmetric end structure, a end is NPT while another RF. It is capable to work under -29℃~150℃.

16 150LB Cast Steel Gate Valve, RF, Body WCB,
16" 150LB Cast Steel Gate Valve, RF, Body WCB, API600

16" 150LB Cast Steel gate valve is made according to API600 standard. The valve body is made of A216 WCB. It has the structural characteristics of Bright pole bracket, body cover bolted connection. Its connection mode is RF. And it has Turbine operation mode.

Lift Check Valve
A105N API602 2" 800LB Lift Check Valve SW

2" 800LB lift check valve is made according to API 602 standard. The valve body is made of ASTM A105N+STL. It has the structural characteristics of lift type. Its connection mode is SW.

Butterfly Valve
4" 150LB Concentric Butterfly Valve WCB Lug API609 Lever

4" 150LB butterfly valve is made according to API 609 standard. The valve body is made of A216 WCB. It has the structural characteristics of center line. Its connection mode is lug (UNC threaded hole, RF 125-250AARH). And it has lever (locking device) operation mode.

Wafer Butterfly Valve
Cast Steel Wafer Type Butterfly Valve 2 Inch 300 LB Lever

China Wafer Type Butterfly Valve Provider DVS Supplies Cast Steel Wafer Butterfly Valve, 2 Inch, Class 300, Lever Operation, for Air, Water, Steam and Gases.

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact